head cleaning epson R230x

1. Turn on the Epson Stylus Photo R230 printer or yours R230x
2. Click Start> Control Panel> select Printers and Faxes> Epson R230
3. Click Select Printer Printing Task prefference on the box that is on the right side of the window or can 

    also right-click on the Epson R230 and select Printing Prefferences
4. Select the Maintenance tab dialog box appears so that these


5.Then select Head Cleaning as shown in the picture above that I put a red circle, it will 
   display a dialog box like this
Select the start like in the picture above that I marked in red arrows, then this machine will do the print head cleaning, ink pumping Please wait for the printer to finish.

Thursday, August 22, 2013

the following ink may have run out calour canon MP250, IP 2270, MP160, iP2700

When the printer is turned on seems OK, but after the print command, it will display Blink 13x Orange on the Canon MP250, MP160, iP2770, iP2700


 the following ink may have run out Color

Blink 13x Orange lights with the picture above, means catrid color reset press the Resume button requires a bit longer until the GREEN light flashes, then release. black catridge also need to be reset and the picture is as follows:

 the following ink may have run out Black



Same way: rather long press the Resume button until the GREEN light flashes, then release.after doing these steps then the printer will return to normal. This often occurs when the cartridge runs out complete refill then installed again.

Wednesday, January 21, 2009

ERROR CODE CANON MP145



Error Code :
E2-2 = No paper (ASF)
E3-3 = Paper jam
E4 = No ink
E5-5 = The ink cartridges are not installed or a non-supported ink cartridge is installed, or the ink cartridges are not installed properly
E8 = Waste ink absorber full, or platen waste ink absorber full
E9 = The connected digital camera / video camera does not support Camera Direct Printing
E14 = The Ink cartridges whose destination are wrong
E15 = Ink cartridge is not installed E16 - Ink remaining is unknown
E16 -E19 = Failed to scan head alignment sheet
E22 = Carriage error
E23 = Paper feed error
E24 = Purge unit error
E25 = ASF(cam) sensor error
E26 = Internal temperature rise error
E27 = Waste ink absorber full or platen waste ink absorber full
E28 = Ink cartridge temperature rise error -
E29 = EEPROM error
E33 = Paper feed position error
E35 15 = USB Host VBUD overcurrent error - USB
E37 17 = Abnormal motor driver error
E40 20 = Other hardware error
E42 22 = Scanner error

ERROR CODE AND RESET CANON MP150 MP160



E9 The connected digital camera / video camera does not support Camera
Direct Printing
E14 The Ink cartridges whose destination are wrong
E15 Ink cartridge is not installed E16 - Ink remaining is unknown
E16 -E19 Failed to scan head alignment sheet
E22 Carriage error
E23 Paper feed error
E24 Purge unit error
E25 ASF(cam) sensor error
E26 Internal temperature rise error
E27 Waste ink absorber full or platen waste ink absorber full
E28 Ink cartridge temperature rise error -
E29 EEPROM error
E33 Paper feed position error
E35 15 USB Host VBUD overcurrent error - USB
E37 17 Abnormal motor driver error
E40 20 Other hardware error
E42 22 Scanner error

Monday, January 19, 2009

Canon MP110




step by step
Reset Printer Canon MP110

1. Enter SERVICE MODE By pressing Menu-Scan-Copy-Scan
2. Enter NVRAM by pressing <--- or ---> then OK
3. Enter CMY ink level by pressing <--- or ---> then OK
4. Select 1 by pressing <--- or ---> then OK
5. Enter K ink level by pressing ---> then OK
6. Select 1 by pressing <--- or ---> then OK
7. Press reset ( design: // )

Saturday, January 10, 2009

Printer Epson Stylus T11



Description
Print speed : Up to 22 ppm black & up to 13 ppm color
Print quality : Up to 1440 rendered dpi black / 5760 dpi color
Cartridge : 73N Black / Cyan / Magenta / Yellow L (91N optional)
Paper Output : A4, A5, A6, C6, DL
PC/MAC Compatible, USB Connectivity, Weight 3.30 kg.


Download Adjustment program epson

Source :Download SSCL.com download software (v4.30)

Monday, February 18, 2008

E061 & E100 Error Codes : iR6570 Series & iR5075 Series

Symptom

* E061-0001 (Potential ON)
* E061-0002 (Potential OFF)
* E100-0001
* E227-0004
Cause
* The pin is broken on the Primary Fan 2 Duct. The Laser Shutter is activated by the pin on the Primary Fan Duct Assembly. The linkage is pinched not allowing the laser shutter to be fully actuated (may also indicate E227-0004). Faulty Laser Scanner Assembly.
* Defective DC Controller PCB Assembly.

Action

1. Check the shutter operation and the pin on the Primary Fan Duct Assembly. If the
pin is broken replace the Primary Fan 2 Duct (iR6570 : FC6-3540-000 / iR5075
FL2-5834-000) or the Primary Fan Duct Assembly (iR6570 : FM2-3074-000 / iR5075
FM2-9694-000). If the Laser Scanner Assembly (iR6570 : FM2-3670-000 / iR5075
FM2-9832-000) has been replaced and error codes E100-0001/ E227-0004 are
intermittently indicated, proceed to the next step.
2. Remove the Primary Fan Duct Assembly (this assembly has a pin on it
that activates the laser shutter).
3. Remove and reinstall the Laser Scanner Assembly.
4. Install the Primary Fan Duct Assembly. This should free the linkage
allowing the laser shutter to be fully actuated.
5. Finally a DC Con clear resolved both of the intermittent issues (E100-0001/
E227-0004)

Blank Image or Dark Fogging Image (Including Blank Areas) and E061-0001 / E061-0002 Errors Occur : iR6570 Series
Approved


Symptom

* Blank copies,Dark fogging
* E061-0001 and E061-0002

Action

When the above error code/image problems are experienced, perform the following:

1. Check the potential sensor wiring harness for any damage. This is caused by the harness being trapped between the hopper assembly and the cable tie head.
2. If the cable is damaged repair or replace as necessary.
3. Reposition the head of the cable ties on the cable guide in a downward position.
4. Input "1" under Service Mode > COPIER > FUNCTION > DPC > DPC, press the OK key and switch the Main power off and on so as to forcibly execute the Potential Control.