Wednesday, February 25, 2004

Canon Error Code, E073, E074, E075, E076, E077, E079, E080, E081, E082, E083, E084, E085, E086, E089, E090, E091, E100,

Tags
E073 The transfer drawer connector or the transfer frame drawer connector is not connected as the front door is closed.
E073 The transfer drawer connector or the transfer frame drawer
connector is not connected as the front door is closed.
E074 The transfer belt unit does not reach the target position within a specific time.
E075 The transfer belt is off to the side.
E076 The transfer belt web is wound up
completely.
E077 The motor inside the transfer belt unit
has a fault.
E079 The home position (to apply pressure) of the transfer drum cleaner unit cannot be detected.
E080 An error occurs in the communication with the multi color unit controller PCB.
E081 The vertical motor clock is faulty.
unit E081 The vertical motor clock is faulty.
E082 The horizontal motor clock is faulty.
E083 The CD unit horizontal movement right sensor is faulty.
E084 The CD unit horizontal movement left sensor is faulty.
E085 The CD unit feeder release sensor is faulty.
E086 The CD unit claw release is faulty.
E089 A malfunction of the multi color
E090 The document feed motor is not
functioning properly.
E091 A failure in the detection of the document feed sensor.
E100 The BD signal cannot be detected within a specific time.

Tuesday, February 24, 2004

Canon Error Code, E051,E054, E055, E060, E061, E062, E063, E064, E065, E066, E067, E068, E069, E070, E071, E072

Tags
E051 The home position of the side registration cannot be detected
within a specific time.
E054 The home position of the duplexing unit feed roller cannot bedetected.
E055 The horizontal registration guide of the duplex unit exceeds its
maximum travel distance.
E060 The home position of the primary corona wire cleaner cannot be
detected within a specific time.
Relateted charging
E061 Specific potential is not be required or the limiter is activated as the
potential is controlled.
E062 The photosensitive drum temperature does not reach a specific
value due to a fault in the photosensitive drum heater, etc.
E063
The home position of the transfer corona wire cleaner cannot be
detected.
An error code is
not to be
indicated.
E064 The setting value for the output from the microcomputer
considerably deviates from the control value of the actual output.
E065 High voltage leakage from the primary corona assembly is
detected.
E066 Signals from the temperature/humidity sensor cannot be detected.
E067
Two or more faults in the primary/ pre (post)-transfer/ transfer/
separation high voltage are detected (including power output
stoppage, electric leakage from the primary corona assembly).
E068 High voltage leakage from or an open circuit in the separation
corona assembly is detected.
E069 High voltage leakage from or an open circuit in the transfer corona
assembly is detected.
E070 The home position of the transfer drum cannot be detected within a specific time.
E071 An image leading edge signal cannot be detected within a specifictime.
E072 A fault in the main motors such as the transfer drum motor, etc.

Sunday, February 22, 2004

Canon Error Code, E021, E022, E023, E024,E025,E026, E027, E028, E029, E029, E030

E021 The rotor fails to rotate and move properly due to a fault in the developing rotor/motor ass'y.
E022 Pressure fails to be applied to the developer after a specific time
passes after the developer is selected.
E023 The developer sleeve motor fails to rotate properly.
E024 The developer cannot be detected. ( not mounted properly.)
E025 Excess current of the toner delivery motor or the cartridge motor is
E030 The total counters are not functioning.
E031 The optional counters are not functioning.
E032 The counters for ASSIST are not functioning. (Disconnection of
counter pulse for ASSIST.)
E040 The lifter position signal fails to be generated due to a lifter clutch
failure.
E041 The paper deck lifter fails to be detected within a specific time.
E042 The roll paper cutting operation is not functioning properly because
the cut motor does not work, etc.
E043 An abnormal signal is detected due to a fault in the pick-up motor
for the 3-cassette deck/3.5K paper deck.
E050
A malfunction of the holding tray. A fault in the side registration is
included.

Saturday, February 21, 2004

Canon Error Code, E013, E014, E015, E016, E017, E018, E019, E020

E013
•The PLL lock is released because waste toner motor is locked up,etc.
•The micro switch employed to detect clogging of waste toner is activated.
•The waste toner case is detected full.
E014
•The PLL lock of the fixing/feeding motor is released.
•Excess current of the feeding motor is detected.
E015
•Clock pulses of the pick-up/duplexing/developing motor fails to be generated or
be detected.
•Excess current of the pick-up/duplexing/developing motor is detected.
E016 Excess current of the reciprocating motor
of the photosensitive drum cleaner unit is detected.
E017 The PLL lock of the drive motor of the holding tray unit is released.
E018 The PLL lock of the drive motor of the oil removing roller is
E019 The waste toner case is detected full although it is not.
E020 The developer fails to be replenished with starter developer properly.

Friday, February 20, 2004

Canon Error Code, E000, E001,E002,E003,E004,E005

E000
The fixing temperature does not go up after turning ON the power
due to a fault in the thermistor or the heater, etc., (e.g. It does not
reach 70°C degrees within 2 min.)
E001
The fixing temperature abnormally goes up due to a fault in the
thermistor or SSR, etc.
E002
The fixing temperature does not reach a specific temperature due
to a fault in the thermistor or the heater, etc.
e.g) The fixing temperature does not go up to 190°C degrees
within 5 min after reaching 70°C degrees.
E003
The fixing temperature drops abnormally after wait time is up due
to a fault in the thermistor, the heater, etc. (e.g. After wait time is
up, the fixing temperature drops to 70°C degrees).
E004
A short circuit in the fixing heater drive circuit (SSR, etc) is
detected.
E005 The fixing web is wound up completely.
E006 The fixing drawer connector is not connected as the front door is closed.
E007 The fixing film is off to the side.
E008
A specific number of copies are made after the machine detects
that fixing oil is out.
E009 The rated voltages of the power supply and the fixing unit do not
E010 Clock pulses fail to be generated or the PLL lock fails to be
released due to a fault in the main motor unit
E011 Excess current flows to the motor control circuit because the main
E012
Clock pulses fail to be generated or the PLL lock is released due to
a fault in the drum motor, etc.

Thursday, February 19, 2004

Ir3200 error code e000677-0004

E677 The external controller is faulty 0001 When a controller for other model is connected. 0002 The condition of initializing communication is faulty. 0101 The external controller fan is faulty. 0004 Come-off detection of the external controller (The external controller fails to detect a connection while the power is ON, even though the controller properly detected it when the power was turned ON). 0008 The communication of the external controller is faulty (When the communication from the external is faulty while communication to the external controller is established). 0080 The communication to a printer is faulty after the external controller properly started up.

Wednesday, February 18, 2004

Error Code E064 Canon iR3300 Series

Symptom

E064 is indicated on the control panel. The error description is: The presence of a high voltage error is communicated by the composite power supply. The output for primary charging, developing, or transfer has deviated from a specific level of voltage.

Cause
* Adjustments in Service Mode are Incorrect
* Transport Assembly is Not Engaging Properly
* Dirty HVT Contacts for Developing Assembly and Charging Rollers
* A Paper Clip on HVT Contacts or Developing Assembly
* Faulty Transfer Roller
* Faulty Static Charge Eliminator
* Defective Composite Power Supply
* Defective DC Controller PCB Assembly

Action

1. Check the values in Service Mode and make sure they correspond to the Service
Label. If the copier receives a spike or surge through the 240V line these values
can change (can also give you blank copies). Take particular note of the Dev Bias
setting. [COPIER > ADJUST > DEVELOP > DE-DC]
2. Make sure the Transport Assembly is engaging properly. The Transfer Roller should
make good contact with the drum. Check condition of screw (XB6-7501-007) and
Pressure Plates (FB5-4816-000 & FB5-4817-000) for the Transport Assembly.
3. Clean HVT contacts for Primary/ Transfer Charging Rollers and Developing
Assembly. Inspect for any paper clips.
4. Replace the Transfer Roller (FF6-0104-000).
5. Replace the Static Charge Eliminator (FF5-7246-000).
6. Replace Composite Power Supply followed by DC Controller PCB Assembly.

Tuesday, February 17, 2004

Canon IR 5000 error code 602-0003

Tags
Wiring
1) Are the connection and the cable of the connector (J1017) on the main controller PCB and the connector (J1551) on the hard disk drive normal? NO: Correct the cable connection.Hard disk drive (HDD), Main controller PCB
2) Try replacing the hard disk drive and downloading the system software.Is the problem corrected?
YES: End. NO: Replace the main controller PCB.
3) HDD unit.
Remove the rear upper cover and the reader rear cover. Remove the three screws, and detach the cover, Remove the two screws and disconnect the two connectors then, remove the HDD unit. Remove the six screws and detach the HDD When mounting the HDD unit,be sure that the flat cable is under the plastic sheet of the HDD upper case.